Atlantic Regenerative Blowers

Atlantic Regenerative Blowers are available in either single (one impeller) or double (two impeller) stage configurations. The impeller is directly connected to the motor shaft, providing powerful force without undue friction. The bearings are outside the compression chamber, ensuring maximum operational reliability under high differential pressure. This low-maintenance, oil-free design provides continuous, dependable service to our customers.

Functional Performance
  • Air Flow: From 50 cfm up to 776 cfm
  • Pressure Capacity: From 47" H20 up to 307" H20
  • Vacuum Capacity: From 40" H20 up to 235.22" H20


Operating Principle
Air or gas is pulled into a side channel (1) through the air inlet (2) and is accelerated by an impeller (3) rotating inside the impeller chamber (4). The resulting pressurized air or gas is discharged through the exhaust outlet (5). This type of operation is also known as a "ring" blower design.

  1. Side Channel
  2. Air Inlet
  3. Impeller
  4. Impeller Chamber
  5. Exhaust Outlet

Cutaway of blower

Accessories
  • Air Knives (Aluminum and Stainless Steel)
  • Stainless Steel Y-branches, Elbows, Hose Clamps, and Piping
  • Stainless Steel Nozzles
  • Stainless Steel Air Knife Support Brackets
  • Air Knife and Blower/Motor Enclosures
  • Available in Powder Coated or Stainless Steel Design
  • Stainless Steel 2, 3, 4, 5 and 6 Outlet Manifolds
  • Stainless Steel HEPA Filters for Clean Room Environments


Design Advantages
  1. Continuous, Low-maintenance Operation
  2. Low Noise (60 - 90 dB)
  3. Saves Space and Electricity
  4. Trouble-free Installation (mounts in any axial direction)
  5. Easy Replacement of Parts

Maintenance - Cleaning
When dust or residue is evident, clean the entire surface of the blower.
Lubrication: After approximately 20,000 hours of operation, or 18 months, replace the grease in the bearings.

Installation
Units can be installed and mounted in any axial direction. For quiet and vibration-free operation, install the unit over a rubber pad. Do not obstruct the cooling system of the motor. Keep all ventilation gratings open and clear. Minimum clearance (1.5") must be maintained between the unit and all side walls or other barriers. Keep all flammable gases and materials away from the unit. After installation be sure to tighten the eye-bolt. The system voltage and frequency is the same as stated on the rating plate +/-5% voltage and/or +/-2% frequency deviation from the rated value without reducing output. Connections should be arranged and attached according to the circuit diagram on the terminal box. The ground wire should be connected to the grounding terminal.

Pacific Regenerative Blower accessories

General Notice
Atlantic Regenerative Blowers are designed for handling air and nonflammable, non-corrosive, non-explosive gases. These blowers are designed for continuous use. Applications involving frequent temperature changes should be evaluated by our technical department prior to installation. Maximum ambient temperature at the inlet is 104 ºF (40ºC). Intake filtration should be used to eliminate solids and impurities from entering the blower.